- Product Categories
- Friendly Links
| Information Name: | Pipe plug wires blocking position measurement / detector / detector |
| Published: | 2014-05-18 |
| Validity: | 0 |
| Specifications: | v-3 |
| Quantity: | 1.00 |
| Price Description: | |
| Detailed Product Description: | Pipe plug wires blocking position measurement / detector / detector, designed for hydropower construction in the second line pipe threading pipe blockage detection point, the probe can go online tube inside two 90 ° elbows, can be positioned to detect blockage point range 5cm in diameter to a small point, the average two minutes to find a blocking point and can detect pvc pipe, kbg tube blockage point iron pipe, galvanized steel pipe and other commonly used (there is water inside the tube can be detected), construction convenient, easy to operate save time and money the provincial labor, water and electricity workers to detect blockage point threading a good helper in! Product Name: Wire clogged pipes blocking position measurement / detector / detector Application: Line pipe (PVC pipe / KBG tube) during the measuring block is suitable to detect the position of the wire duct blockage hydropower construction on the building site, you can make jam location accurate to within 5cm range. Product of the parts Name: signal generator, signal generator switch, power indicator signal generator, detector lights, power light detector, the detector distance adjustment knob, handheld detector, wear lead plugs, probes, wear lead as shown below. Product description: 1. Before use make sure you have placed batteries. Place the hand-held detector 1.5V 5 batteries 4, the signal transmitter placed inside a 9V battery; (battery configuration) 2. Wear a lead plug into the generator outlet, turn signal generator switch, then the signal generator lights green light, indicating that the signal generator 3. Open handheld detector rotary switch, you can hear the "click" sound, the corresponding green power indicator light, red light is a signal detector knob clockwise to improve detection sensitivity, detection distance; conversely low sensitivity and detection range near. When the hand-held detector probe near the needle threader, handheld detector will sound an alarm issued (hereinafter: Music Fur Elise), while the red signal indicator lights; 4 knob to adjust the detector, estimate. Probably wall thickness, so adjust the detector and the thickness of the probe remain effective detection distance of about 15 ~ 20cm, when the line pipe buried deeper, this distance may be appropriate to increase, shallow, this distance may be appropriate to reduce the , then keep the knob stationary detectors, even below the detection process is also not easy to spin the knob. 5 Then slowly wear lead probe into the tube from the mouth line blockage, can not move forward until the date, location of the probe that is blocked at this location; 6 handheld detector, roughly along the buried line pipe to detect this The best course is always to keep the detector knob does not move; 7 near the pipeline if the internal probe, handheld detector alarm sound will be issued, with the change in the distance between the probe, the alarm sounds and the red lights will synchronize to improve or lower, the song sounds from the probe recent highest brightest lights; 8 to reduce false positives, sway back and forth in a position to detect suspicious to determine the final location of the blockage; 9 to find the location of the blockage, turn off the detector. (Rotate the knob counterclockwise until you hear a "click" sound) and signal generator switch, so the battery is depleted. Note: 1, After finding the blocking position, please wear a lead pull put in a safe place and then tick reliable tank excavation and construction; 2, when used in iron pipes, detection range is slightly reduced, but the distance is 10cm to ensure the ; 3, when probing handheld detectors do not have to close the wall or floor, while maintaining an appropriate distance from the wall when the probe can quickly locate the blockage; 4, when the detector head is parallel with the probe would be more sensitive, perpendicular sensitivity is relatively low, but does not affect the outcome of the judgment; 5, due to the signal generator power consumption, significantly reduced if the detection range, please change the 9V battery, if necessary, please feel free to turn off the signal generator; unified national price 600 yuan / sets support cash on delivery, nationwide shipping (Xinjiang, Tibet, Qinghai, Taiwan, Macau, Hong Kong not)! |
Admin>>>
You are the 4963 visitor
Copyright © GuangDong ICP No. 10089450, China metal building materials mall All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 4963 visitor
Copyright © GuangDong ICP No. 10089450, China metal building materials mall All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
| No.12928916

